Rated power

230 to 240 V single phase amperage

400 to 415 V three phase amperage

Sense Elite 6 and Sense Combi Elite 6

6.6 kW

29 A

10 A per phase

Sense Elite 8 and Sense Combi Elite 8

8 kW

35 A

12 A per phase

Sense Elite 10 and Sense Combi Elite 10

10.5 kW

Not approved for single phase in Europe

16 A per phase

Crown Elite 6 and Crown Combi Elite 6

6.6 kW

29 A

10 A per phase

Crown Elite 8 and Crown Combi Elite 8

8 kW

35 A

12 A per phase

Crown Elite 10 and Crown Combi Elite 10

10.8 kW in current manuals

Not approved for single phase in Europe

16 A per phase

Heater

Power

230 V single phase

400 V three phase

Harvia Vega BC60

6 kW

35 A fuse

3 × 10 A fuses

Harvia Vega BC80

8 kW

35 A fuse

3 × 16 A fuses

Harvia Vega BC90

9 kW

50 A fuse

3 × 16 A fuses

Harvia The Wall SW80

8 kW

35 A fuse

3 × 16 A fuses

HUUM DROP 6

6 kW

32 A fuse

3 × 10 A fuses

HUUM DROP 9

Confirm version

40 A fuse in current EU table

3 × 16 A fuses in current EU table

HUUM HIVE 12

12 kW

Not listed in current EU specification

3 × 20 A fuses

Preparing Your Electrics Before Sauna Installation Day

To ensure your new sauna installation goes as smoothly as possible, all necessary electrical work must be completed before your scheduled installation day.

This includes having the correct electrical supply, cabling, circuit protection and isolation arrangements in place, ready for your sauna heater to be connected.

As electrical requirements vary depending on the sauna heater and control system, we recommend arranging for a suitably qualified electrician to assess and complete the required work well in advance of delivery.

At Take Wellness, we are happy to guide you through the electrical requirements in the build up to your installation.

Once your sauna and heater have been selected, we can provide the relevant electrical specifications and manufacturer information for your electrician. We are also available to answer questions throughout the process and help clarify what needs to be prepared.

We recommend confirming the electrical arrangements with us before installation day, including who will be responsible for the final electrical connection.

Having everything ready in advance helps prevent delays on the day and allows our installation team to concentrate on getting your new sauna set up and ready to enjoy.

Questions about your order?

Contact Take Wellness with your order reference and sauna model before electrical work begins. We can help identify the heater and the relevant manufacturer documents for your electrician.

This guide supports advance planning. Installation must follow the manual supplied with the equipment and the electrical requirements applicable to your property.

Manufacturer references

Use the manual matching the supplied equipment. The linked manufacturer documents support the customer tables; rounded retailer descriptions are not used as electrical design instructions.

1 Harvia Vega BC60 electrical data

2 Harvia Vega BC80 electrical data

3 Harvia Vega BC90 electrical data

4 Harvia The Wall SW80 electrical data

5 HUUM DROP European specifications and manual

6 HUUM HIVE European specifications and manual

7 Tylö Sense Elite installation manual 2900 5470

8 Tylö Sense Combi installation manual 2900 5410

9 Tylö Crown Elite installation manual 2900 5500

10 Tylö Crown Combi installation manual 2900 5520

11 Tylö Sense Sport installation manual

12 Helo Hanko STJ manufacturer manual Table 2

13 Tylö 2025 European catalogue infrared technical information

14 Tylö T 810 installation and user manual